Opened 15 years ago

Closed 15 years ago

#60 closed defect (fixed)

Too many initial conditions

Reported by: Argimiro Resende Secchi Owned by: Rafael de Pelegrini Soares
Priority: major Milestone:
Component: EMSO Version: 0.9.51
Keywords: Cc:

Description

When the number of initial conditions is greater than the dynamic degree of freedom the following warning message is given: FlowSheet? xxx has too many initial conditions. However, the extra given initial conditions are not checked against their correct values. Therefore, a warning message should be provided informing which extra initial condition is not consistent, given its correct value.

Change History (1)

comment:1 Changed 15 years ago by Rafael de Pelegrini Soares

Resolution: fixed
Status: newclosed

When a FlowSheet? has too many initial conditions some of them are just ignored. In the development version a new warning message was added for each ignored initial condition:

FlowSheet 'XXX' has too many initial conditions
Ignored initial condition 'X=X0'
Ignored initial condition 'Z=Z0'
Note: See TracTickets for help on using tickets.