#135 | worksforme | EMSO crashes following the tutorial in manual | ||
Description |
I am try using EMSO, with VRtherm plugin following the steps in EMSO manual I have created everything like the tutorial in page, 12 section 2.4, but then when I run EMSO just try open the debug and close. |
|||
#40 | fixed | EMSO bug without PP | ||
Description |
EMSO quits abnormaly when checking consistency if the Properties Package License is expired. |
|||
#81 | fixed | Displaying temperature results in Cdeg | ||
Description |
A easy way to display temperature results in Celsius degrees could be the creation of a variable like 'Cdeg as temperature;' and a equation like this 'Cdeg = Inlet.T - 273.15 * 'K';' in 'sink' model. Similar to input may be developed in 'source' model. The user should notice the result will appear with [K] UOM anyway. |