#*-------------------------------------------------------------------- * * EMSO sample file. * * heater * *--------------------------------------------------------------------*# using "heat_exchangers/heater"; FlowSheet Cooler_Project DEVICES cooler as Cooler; streamcold1 as stream_therm; streamcold2 as stream_therm; CONNECTIONS streamcold1 to cooler.Inlet(1); streamcold2 to cooler.Inlet(2); PARAMETERS PP as CalcObject (File="vrpp"); NComp as Integer; Ninlet as Integer (Brief="Number of Inlet Streams"); SET PP.LiquidModel = "RK"; PP.VapourModel = "RK"; PP.Components = ["water","methanol"]; NComp = PP.NumberOfComponents; Ninlet = 2; SPECIFY streamcold1.F = 100 * "kmol/h"; streamcold1.P = 1 * "atm"; streamcold1.T = 100 * "K"; streamcold1.v = 0; streamcold1.z = [1,0]; streamcold2.F = 20* "kmol/h"; streamcold2.P = 1 * "atm"; streamcold2.T = 100 * "K"; streamcold2.v = 0; streamcold2.z = [0,1]; cooler.Outlet.T = 70*"K"; cooler.Outlet.P = 1 * "atm"; OPTIONS mode = "steady"; outputLevel = "all"; relativeAccuracy = 1e-8; end