Changeset 807


Ignore:
Timestamp:
Jul 31, 2009, 5:23:27 PM (13 years ago)
Author:
gerson bicca
Message:

added temperature indicator

File:
1 edited

Legend:

Unmodified
Added
Removed
  • branches/gui/eml/stage_separators/tank.mso

    r805 r807  
    664664        Level           as length               (Brief="liquid height", Protected=true);
    665665        Across          as area                 (Brief="Vessel cylinder shell Cross section area", Hidden=true, Symbol="A_{cross}");
    666         #vfrac          as positive     (Brief="Vapourization fraction", Symbol="\phi", Protected=true);
    667         #Pratio                 as positive             (Brief = "Pressure Ratio", Symbol ="P_{ratio}", Protected=true);       
    668666        Pdrop           as press_delta  (Brief = "Pressure Drop", DisplayUnit = 'kPa', Symbol ="\Delta P", Protected=true);
    669667
    670 out     LI as control_signal    (Brief="Level Indicator", PosX=1, PosY=0.6, Protected=true);
     668out     LI as control_signal    (Brief="Level Indicator", PosX=1, PosY=0.7, Protected=true);
     669out     TI as control_signal    (Brief="Temperature Indicator", PosX=1, PosY=0.6, Protected=true);
    671670
    672671INITIAL
     
    749748"Mol fraction normalisation"
    750749        sum(OutletLiquid.z)=sum(OutletVapour.z);
    751 
    752 #"Vaporization Fraction"
    753         #OutletVapour.F = (InletLiquid.F + InletVapour.F)* vfrac;
    754750
    755751"Liquid Volume"
     
    773769        OutletLiquid.P  = InletLiquid.P - Pdrop;
    774770
    775 #"Pressure Ratio"
    776         #OutletLiquid.P = InletLiquid.P * Pratio;
    777 
    778771"Geometry Constraint"
    779772        Vtotal = LiquidHoldup * vL + VapourHoldup * vV;
     
    781774"Level indicator"
    782775        LI*Vtotal= Vfilled;
     776
     777"Temperature indicator"
     778        TI * 'K' = OutletLiquid.T;
    783779
    784780"Liquid Level"
Note: See TracChangeset for help on using the changeset viewer.