Message:

Adding standard volumetric flow in source and sink.

File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/eml/streams.mso

    r669 r753  
    175175                  CompositionBasis              as Switcher             (Brief = "Molar or Mass Composition", Valid = ["Molar", "Mass"], Default="Molar");
    176176                  ValidPhases                           as Switcher             (Brief = "Valid Phases for Flash Calculation", Valid = ["Vapour-Only", "Liquid-Only","Vapour-Liquid"], Default="Vapour-Liquid");
    177        
    178 
     177                  T_std                                         as temperature (Brief = "Standard temperature", Hidden=true, Default = 298.15);
     178                  P_std                                         as pressure (Brief = "Standard pressure", Hidden=true, Default = 1);
    179179SET
    180180
     
    189189        Fw                                                      as flow_mass            (Brief = "Stream Mass Flow");
    190190        Fvol                                    as flow_vol        (Brief = "Volumetric Flow");
     191        Fvol_std                                as flow_vol        (Brief = "Standard Volumetric Flow (1 atm, 20 C)");
    191192        T                                                               as temperature  (Brief = "Stream Temperature");
    192193        T_Cdeg                                          as temperature  (Brief = "Temperature in °C", Lower=-200);
     
    198199        Mw                                              as molweight                    (Brief = "Average Mol Weight",Protected=true);
    199200        vm                                              as volume_mol           (Brief = "Molar Volume",Protected=true);       
     201        vm_std                                  as volume_mol           (Brief = "Standard Molar Volume",Protected=true);       
    200202        rho                                             as dens_mass                    (Brief = "Stream Mass Density",Protected=true);
    201203        rhom                                            as dens_mol                     (Brief = "Stream Molar Density",Protected=true);
     
    242244        vm = PP.LiquidVolume(Outlet.T, Outlet.P, x);
    243245
     246"Standard Molar Volume"
     247        vm_std = PP.LiquidVolume(T_std, P_std, x);
     248
    244249        case "Vapour-Only":
    245250
     
    259264        vm = PP.VapourVolume(Outlet.T, Outlet.P, y);
    260265
     266"Standard Molar Volume"
     267        vm_std = PP.VapourVolume(T_std, P_std, y);
    261268
    262269        case "Vapour-Liquid":
     
    269276
    270277"Molar Volume"
    271         vm = (1-Outlet.v)*PP.LiquidVolume(Outlet.T, Outlet.P, x) + Outlet.v*PP.VapourVolume(Outlet.T,Outlet.P,y);
     278        vm = (1-Outlet.v)*PP.LiquidVolume(Outlet.T, Outlet.P, x) + Outlet.v*PP.VapourVolume(Outlet.T, Outlet.P, y);
     279
     280"Standard Molar Volume"
     281        vm_std = (1-Outlet.v)*PP.LiquidVolume(T_std, P_std, x) + Outlet.v*PP.VapourVolume(T_std, P_std, y);
    272282
    273283end
     
    287297"Volumetric Flow"
    288298        Fvol = Outlet.F*vm ;
    289        
     299
     300"Standard Volumetric Flow"
     301        Fvol_std = Outlet.F*vm_std ;
     302
    290303"Temperature in °C"
    291304        T_Cdeg = Outlet.T - 273.15 * 'K';
     
    431444                  M(NComp)      as molweight    (Brief = "Component Mol Weight");
    432445                  rhoModel              as Switcher             (Brief = "Density model", Valid = ["volume", "correlation"], Default="volume");
    433        
     446                  T_std                 as temperature  (Brief = "Standard temperature", Hidden=true, Default = 298.15);
     447                  P_std                 as pressure             (Brief = "Standard pressure", Hidden=true, Default = 1);
     448
    434449        SET
    435450
     
    444459        Mw                              as molweight    (Brief = "Average Mol Weight");
    445460        vm                              as volume_mol   (Brief = "Molar Volume");       
     461        vm_std                  as volume_mol   (Brief = "Standard Molar Volume",Protected=true);       
    446462        rho                             as dens_mass    (Brief = "Stream Mass Density");
    447463        rhom                    as dens_mol             (Brief = "Stream Molar Density");
    448464        Fw                              as flow_mass    (Brief = "Stream Mass Flow");
    449465        Fvol            as flow_vol     (Brief = "Volumetric Flow");
     466        Fvol_std        as flow_vol     (Brief = "Standard Volumetric Flow (1 atm, 20 C)");
    450467        s                               as entr_mol             (Brief = "Stream Entropy");
    451468        T_Cdeg                  as temperature  (Brief = "Temperature in °C", Lower=-200);
     
    475492
    476493        "Molar Volume"
    477         vm = (1-v)*PP.LiquidVolume(Inlet.T, Inlet.P, x) + v*PP.VapourVolume(Inlet.T,Inlet.P,y);
    478        
     494        vm = (1-v)*PP.LiquidVolume(Inlet.T, Inlet.P, x) + v*PP.VapourVolume(Inlet.T, Inlet.P, y);
     495
     496        "Standard Molar Volume"
     497        vm_std = (1-v)*PP.LiquidVolume(T_std, P_std, x) + v*PP.VapourVolume(T_std, P_std, y);
     498
    479499        "Volumetric Flow"
    480500        Fvol = Inlet.F*vm ;
    481        
     501
     502        "Standard Volumetric Flow"
     503        Fvol_std = Inlet.F*vm_std ;
     504
    482505        "Mass Fraction"
    483506        zmass = M*Inlet.z / Mw;
Note: See TracChangeset for help on using the changeset viewer.