Ignore:
Timestamp:
Oct 2, 2008, 10:20:25 PM (14 years ago)
Author:
gerson bicca
Message:

improved heater/cooler model

File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/eml/heat_exchangers/heater.mso

    r650 r657  
    132132 VARIABLES
    133133
    134 in  InletQ              as energy_stream        (Brief ="Inlet Heat Stream", PosX=0.5, PosY=1, Symbol="_{out}");
     134out  OutletQ                    as energy_stream        (Brief ="Inlet Heat Stream", PosX=0.5, PosY=0, Symbol="_{out}");
    135135
    136136 EQUATIONS
    137137
    138138 "Duty Specification"
    139         InletQ.Q = -Duty;
     139        OutletQ.Q = -Duty;
    140140
    141141end