Ignore:
Timestamp:
Aug 23, 2008, 7:06:59 PM (15 years ago)
Author:
Argimiro Resende Secchi
Message:

Updating tray efficiency models.

File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/eml/stage_separators/tray_Eff.mso

    r593 r607  
    253253        fi as fraction (Brief="Fractional perforated tray area(hole area/ bubbling area)");
    254254        Ts as length (Brief="Tray spacing");
    255         T as length (Brief="Tray thickness");
    256         psi as Real (Brief="Correction factor of liquid entrainment in dualflow trays");
    257         psi1 as Real (Brief="Correction factor of weeping in dualflow trays");
     255        T as length (Brief="Tray thickness");   
    258256        tray_type as Switcher (Valid = ["Dualflow", "Downcomer"], Default= "Downcomer");
    259257outer   iLK as Integer (Brief="Pseudo-binary ligth key index");
     
    389387        Emv1 as positive (Brief="Murphree tray efficiency");
    390388       
     389        psi as Real (Brief="Correction factor of liquid entrainment in dualflow trays");
     390        psi1 as Real (Brief="Correction factor of weeping in dualflow trays");
     391       
    391392        hb as length (Brief="Height on spray regime");     
    392393        l as positive (Brief="Fraction of entrained liquid");     
Note: See TracChangeset for help on using the changeset viewer.