Changeset 596 for branches/gui/eml/pressure_changers/turbine.mso
- Timestamp:
- Aug 12, 2008, 12:57:24 AM (14 years ago)
- File:
-
- 1 edited
Legend:
- Unmodified
- Added
- Removed
-
branches/gui/eml/pressure_changers/turbine.mso
r554 r596 21 21 using "streams"; 22 22 23 #Needs to be reformulated 24 23 25 Model HidraulicTurbine 24 26 ATTRIBUTES 25 27 Pallete = true; 26 28 Icon = "icon/HidraulicTurbine"; 27 Brief = "Model of a Hidraulic Turbine."; 28 Info = 29 "== Assumptions == 30 * Steady State; 31 * Only Liquid; 32 * Adiabatic; 33 * Isentropic. 34 35 == Specify == 36 * the inlet stream; 37 * the Pressure Increase (Pdiff) OR the outlet pressure (Outlet.P); 38 * the Turbine efficiency (Eff); 39 * the Brake efficiency (Meff); 40 * the Volumetric expansivity (Beta). 41 "; 29 Brief = "Testing Model of a Hidraulic Turbine."; 42 30 43 31 PARAMETERS … … 58 46 rho as dens_mass (Brief = "Specific Mass"); 59 47 Cp as cp_mol (Brief = "Heat Capacity"); 60 in Inlet as stream (Brief = "Inlet stream", PosX=0, PosY=0.5086, Symbol="_{in}"); 61 out Outlet as stream (Brief = "Outlet stream", PosX=1, PosY=0.5022, Symbol="_{out}"); 48 in Inlet as stream (Brief = "Inlet stream", PosX=0.05, PosY=0.0, Symbol="_{in}"); 49 out Outlet as stream (Brief = "Outlet stream", PosX=0.65, PosY=1, Symbol="_{out}"); 50 out WorkOut as power (Brief = "Work Outlet", PosX=1, PosY=0.46); 62 51 63 52 SET … … 89 78 "Calculate Brake Power" 90 79 BPower = FPower * Eff; 80 81 BPower = WorkOut; 91 82 92 83 "Calculate Outlet Temperature"
Note: See TracChangeset
for help on using the changeset viewer.