Changeset 546 for trunk/eml/heat_exchangers/heater.mso
- Timestamp:
- Jun 27, 2008, 2:34:14 PM (15 years ago)
- File:
-
- 1 edited
Legend:
- Unmodified
- Added
- Removed
-
trunk/eml/heat_exchangers/heater.mso
r489 r546 29 29 30 30 PARAMETERS 31 outer PP as Plugin(Brief="Physical Properties", Type="PP");31 outer PP as Plugin (Brief="Physical Properties", Type="PP"); 32 32 outer NComp as Integer (Brief="Number of Components"); 33 Ninlet as Integer (Brief="Number of Inlet Streams");34 Kvalues as Switcher(Brief="Option for Display Phase Equilibrium K-values",Valid=["yes","no"], Default="yes");33 Ninlet as Integer (Brief="Number of Inlet Streams"); 34 Kvalues as Switcher (Brief="Option for Display Phase Equilibrium K-values",Valid=["yes","no"], Default="yes"); 35 35 36 36 VARIABLES 37 QDuty as power(Brief = "Actual Duty",Symbol="Q_{Duty}");38 Vfrac as fraction(Brief = "Vapor fraction Outlet Stream",Symbol="V_{frac}");39 Lfrac as fraction(Brief = "Liquid fraction Outlet Stream",Symbol="L_{frac}");40 Kvalue(NComp) as Real (Brief = "Phase Equilibrium K-values",Symbol="K_{value}");41 Pratio(Ninlet ) 42 Pdrop(Ninlet ) 43 in Inlet(Ninlet ) as stream (Brief = "Inlet Streams", PosX=0, PosY=0.4833, Symbol="^{in}");44 out Outlet as streamPH (Brief = "Outlet Stream", PosX=1, PosY=0.4782, Symbol="^{out}");37 QDuty as power (Brief = "Actual Duty",Symbol="Q_{Duty}"); 38 Vfrac as fraction (Brief = "Vapor fraction Outlet Stream",Symbol="V_{frac}"); 39 Lfrac as fraction (Brief = "Liquid fraction Outlet Stream",Symbol="L_{frac}"); 40 Kvalue(NComp) as Real (Brief = "Phase Equilibrium K-values",Symbol="K_{value}"); 41 Pratio(Ninlet ) as positive (Brief = "Pressure Ratio for each stream", Symbol ="P_{ratio}"); 42 Pdrop(Ninlet ) as press_delta (Brief = "Pressure Drop for each stream", DisplayUnit = 'kPa', Symbol ="\Delta P"); 43 in Inlet(Ninlet ) as stream (Brief = "Inlet Streams", PosX=0, PosY=0.4833, Symbol="^{in}"); 44 out Outlet as streamPH (Brief = "Outlet Stream", PosX=1, PosY=0.4782, Symbol="^{out}"); 45 45 46 46 EQUATIONS … … 101 101 102 102 VARIABLES 103 in InletQ as energy_stream (Brief ="Inlet Heat Stream", PosX=0.1662, PosY=1, Symbol="_{out}"); 103 104 in InletQ as energy_stream (Brief ="Inlet Heat Stream", PosX=0.5, PosY=1, Symbol="_{out}"); 104 105 105 106 EQUATIONS 106 107 "Net Duty" 107 108 InletQ.Q = QDuty; 109 108 110 end 109 111 … … 126 128 127 129 VARIABLES 128 in InletQ as energy_stream (Brief ="Inlet Heat Stream", PosX=0.8245, PosY=1, Symbol="_{out}"); 130 131 in InletQ as energy_stream (Brief ="Inlet Heat Stream", PosX=0.5, PosY=1, Symbol="_{out}"); 129 132 130 133 EQUATIONS 131 134 "Net Duty" 132 135 InletQ.Q = -QDuty; 136 133 137 end
Note: See TracChangeset
for help on using the changeset viewer.