Changeset 515 for trunk/sample


Ignore:
Timestamp:
May 14, 2008, 2:45:02 PM (15 years ago)
Author:
Paula Bettio Staudt
Message:

Updated some examples

File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/sample/stage_separators/sample_column.mso

    r500 r515  
    555555        reb.z = [0.16, 0.542, 0.013, 0.008, 0.277];
    556556
    557         sec.dP = 0.008 * 'atm';
    558 
    559         SET
    560         sec.H = 4 * 'm';
    561         sec.NStages = 8;
     557        sec.dP = 0.008 * 'atm'; #queda de pressao na secao!
     558
     559        SET
     560        sec.H = 4 * 'm';#altura do recheio
     561        sec.NStages = 8; #numero de estagios teoricos do recheio
    562562        sec.stage.Q = 0 * 'kW';
    563563        sec.stage.d = 1.009 * 'm';
     
    565565        sec.stage.e = 0.951;
    566566        sec.stage.a = 112.6 * 'm^2/m^3';
    567         sec.stage.Qsil = 0.1;
     567        sec.stage.Qsil = 0.1;#coeficiente de resistencia do recheio
    568568
    569569        INITIAL
     
    631631        col.pump1.dP = 16 * 'kPa';
    632632
    633         col.dP = 0.024 * 'atm';
    634 
    635         SET
    636         col.H = 3.5 * 'm';
    637         col.NStages = 8;
     633        col.dP = 0.024 * 'atm'; #queda de pressao entre o topo e o fundo da coluna.
     634
     635        SET
     636        col.H = 3.5 * 'm'; # altura de recheio
     637        col.NStages = 8; # numero de estagios teoricos do recheio
    638638        col.stage.Q = 0 * 'kW';
    639639        col.stage.d = 2.24 * 'ft';
     
    646646        col.reb.V = 2 * 'm^3';
    647647        col.reb.Across = 1 * 'm^2';
    648         col.stage.Qsil = 2;
     648        col.stage.Qsil = 2; # coeficiente de resistencia do recheio
    649649       
    650650        INITIAL
     
    823823        col.pump1.dP = 16 * 'kPa';
    824824       
    825         col.dP = 0.024  * 'atm';
    826 
    827         SET
    828         col.H = 3.5 * 'm';
    829         col.NStages = 8;
     825        col.dP = 0.024  * 'atm'; #queda de pressao entre o topo e o fundo da coluna
     826
     827        SET
     828        col.H = 3.5 * 'm'; #altura do recheio
     829        col.NStages = 8; #numero de estagios teoricos do recheio
    830830        col.stage.Q = 0 * 'kW';
    831831        col.stage.d = 2.24 * 'ft';
     
    839839        col.reb.Across = 1 * 'm^2';
    840840
    841         col.stage.Qsil = 2;
     841        col.stage.Qsil = 2; #coeficiente de resistencia do recheio
    842842
    843843        # Controllers type
Note: See TracChangeset for help on using the changeset viewer.