Message:

fixed signal on enthalpy equation

File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/eml/heat_exchangers/DoublePipeIncr.mso

    r432 r437  
    766766
    767767"Incremental Enthalpy Inner Stream"
    768         Inner.HeatTransfer.Enth(i) = (1-InletInner.v)*PP.LiquidEnthalpy(Inner.HeatTransfer.Tlocal(i), Inner.PressureDrop.Plocal(i), InletInner.z) - InletInner.v*PP.VapourEnthalpy(Inner.HeatTransfer.Tlocal(i), Inner.PressureDrop.Plocal(i), InletInner.z);
     768        Inner.HeatTransfer.Enth(i) = (1-InletInner.v)*PP.LiquidEnthalpy(Inner.HeatTransfer.Tlocal(i), Inner.PressureDrop.Plocal(i), InletInner.z) + InletInner.v*PP.VapourEnthalpy(Inner.HeatTransfer.Tlocal(i), Inner.PressureDrop.Plocal(i), InletInner.z);
    769769
    770770"Incremental Enthalpy Outer Stream"
    771         Outer.HeatTransfer.Enth(i) = (1-InletOuter.v)*PP.LiquidEnthalpy(Outer.HeatTransfer.Tlocal(i), Outer.PressureDrop.Plocal(i), InletOuter.z) - InletOuter.v*PP.VapourEnthalpy(Outer.HeatTransfer.Tlocal(i), Outer.PressureDrop.Plocal(i), InletOuter.z);
     771        Outer.HeatTransfer.Enth(i) = (1-InletOuter.v)*PP.LiquidEnthalpy(Outer.HeatTransfer.Tlocal(i), Outer.PressureDrop.Plocal(i), InletOuter.z) + InletOuter.v*PP.VapourEnthalpy(Outer.HeatTransfer.Tlocal(i), Outer.PressureDrop.Plocal(i), InletOuter.z);
    772772
    773773end