Changeset 369


Ignore:
Timestamp:
Sep 17, 2007, 3:02:29 PM (16 years ago)
Author:
gerson bicca
Message:

fixed port positions in heat exchanger model

File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/eml/heat_exchangers/HeatExchangerDetailed.mso

    r355 r369  
    3333VARIABLES
    3434
    35 in  InletTube   as stream               (Brief="Inlet Tube Stream", PosX=0, PosY=0.4915, Symbol="_{inTube}");
    36 out OutletTube  as streamPH     (Brief="Outlet Tube Stream", PosX=1, PosY=0.4915, Symbol="_{outTube}");
    37 in  InletShell  as stream               (Brief="Inlet Shell Stream", PosX=0.5237, PosY=1, Symbol="_{inShell}");
    38 out OutletShell as streamPH     (Brief="Outlet Shell Stream", PosX=0.5237, PosY=0, Symbol="_{outShell}");
     35in  InletTube   as stream               (Brief="Inlet Tube Stream", PosX=0.08, PosY=0, Symbol="_{inTube}");
     36out OutletTube  as streamPH     (Brief="Outlet Tube Stream", PosX=0.08, PosY=1, Symbol="_{outTube}");
     37in  InletShell  as stream               (Brief="Inlet Shell Stream", PosX=0.2237, PosY=0, Symbol="_{inShell}");
     38out OutletShell as streamPH     (Brief="Outlet Shell Stream", PosX=0.8237, PosY=1, Symbol="_{outShell}");
    3939       
    4040        Details         as Details_Main         (Brief="Details in Heat Exchanger");