Ignore:
Timestamp:
Aug 30, 2007, 1:12:27 PM (15 years ago)
Author:
Argimiro Resende Secchi
Message:

Fixing some wiki notation.

File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/eml/pressure_changers/valve.mso

    r351 r353  
    2727        Brief           = "Model of a valve.";
    2828        Info            =
    29         "Model of valves:
    30          * Linear;
    31          * Parabolic;
    32          * Equal;
    33          * Quick;
    34          * Hyperbolic.
     29"== Model of valves ==
     30* Linear;
     31* Parabolic;
     32* Equal;
     33* Quick;
     34* Hyperbolic.
    3535       
    36         Assumptions:
    37          * Steady State;
    38          * Liquid;
    39          * Isentalpic.
     36== Assumptions ==
     37* Steady State;
     38* Liquid;
     39* Isentalpic.
    4040       
    41         Specify:
    42          * the valve type;
    43          * the inlet stream;
    44          * the Volumetric Flow (Qv);
    45          * the Valve Coefficient (cv);
    46          * the opening (x).
    47         ";
     41== Specify ==
     42* the valve type;
     43* the inlet stream;
     44* the Volumetric Flow (Qv);
     45* the Valve Coefficient (cv);
     46* the opening (x).
     47";
    4848               
    4949        PARAMETERS
     
    142142        Brief           = "Model of a very simple valve - used in distillation column models.";
    143143        Info            =
    144         "Assumptions:
    145          * no flashing liquid in the valve;
    146          * the flow in the valve is adiabatic;
    147          * dynamics in the valve are neglected;
    148          * linear flow type.
     144"== Assumptions ==
     145* no flashing liquid in the valve;
     146* the flow in the valve is adiabatic;
     147* dynamics in the valve are neglected;
     148* linear flow type.
    149149       
    150         Specify:
    151          * the inlet stream
    152          * the plug position (x) OR outlet temperature (Outlet.T) OR outlet pressure (Outlet.P)
     150== Specify ==
     151* the inlet stream
     152* the plug position (x) OR outlet temperature (Outlet.T) OR outlet pressure (Outlet.P)
    153153       
    154154        OR             
    155155       
    156          * the inlet stream excluding its flow (Inlet.F)
    157          * the outlet pressure (Outlet.P) OR outlet flow (Outlet.F)
    158          * the plug position (x)
    159         ";
     156* the inlet stream excluding its flow (Inlet.F)
     157* the outlet pressure (Outlet.P) OR outlet flow (Outlet.F)
     158* the plug position (x)
     159";
    160160
    161161        PARAMETERS
Note: See TracChangeset for help on using the changeset viewer.