Ignore:
Timestamp:
Jun 16, 2007, 7:23:13 PM (15 years ago)
Author:
gerson bicca
Message:

updated ATTRIBUTES section in heat exchangers

File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/eml/heat_exchangers/heater.mso

    r197 r284  
    1212* EMSO is distributed under the therms of the ALSOC LICENSE as
    1313* available at http://www.enq.ufrgs.br/alsoc.
    14 *
    15 *---------------------------------------------------------------------
    16 * Model of a Heater and Cooler
    17 *
    18 *       Streams:
    19 *               * Inlet(Ninlet) streams ....    at least one material stream
    20 *               * Outlet stream             ....        one material stream
    21 *
    22 *       Purpose:
    23 *               * Determines thermal and phase conditions of outlet stream
    24 *
    2514*----------------------------------------------------------------------
    2615* Author: Gerson Balbueno Bicca
     
    7463ATTRIBUTES
    7564        Pallete         = true;
    76         Brief           = "Heater";
     65        Brief           = "Model of a Heater";
    7766        Info            =
    78         "write some information";
     67        "This model determines thermal and phase conditions of outlet stream";
    7968       
    8069EQUATIONS
     
    8978ATTRIBUTES
    9079        Pallete         = true;
    91         Brief           = "Cooler";
     80        Brief           = "Model of a Cooler";
    9281        Info            =
    93         "write some information";
     82        "This model determines thermal and phase conditions of outlet stream";
    9483       
    9584EQUATIONS
Note: See TracChangeset for help on using the changeset viewer.