Ignore:
Timestamp:
Jan 29, 2007, 1:50:41 PM (15 years ago)
Author:
gerson bicca
Message:

updated models for the new language

File:
1 edited

Legend:

Unmodified
Added
Removed
  • branches/newlanguage/sample/heat_exchangers/Sample_DoublePipe_Series.mso

    r100 r139  
    88DEVICES
    99
    10         Pipe(2)         as DoublePipe_LMTD;
    11         streamhot       as streamTP;
    12         streamcold      as streamTP;
     10        Pipe(2)                 as DoublePipe_LMTD;
     11        streamhot       as source;
     12        streamcold      as source;
    1313
    1414CONNECTIONS
    1515
    16         streamhot                       to Pipe(1).Inlet.Hot;
     16        streamhotOutlet.        to Pipe(1).Inlet.Hot;
    1717        Pipe(1).Outlet.Hot      to Pipe(2).Inlet.Hot;
    1818       
    19         streamcold                      to Pipe(1).Inlet.Cold;
    20         Pipe(1).Outlet.Cold to Pipe(2).Inlet.Cold;
     19        streamcoldOutlet.       to Pipe(1).Inlet.Cold;
     20        Pipe(1).Outlet.Cold   to Pipe(2).Inlet.Cold;
    2121       
    2222PARAMETERS
     
    5555#++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
    5656
    57         streamhot.F = 100               * "kmol/h";
    58         streamhot.T = (70+273.15)   * "K";
    59         streamhot.P = 5                         * "bar";
    60         streamhot.z = [1,0];
     57        streamhot.Outlet.F = 100                * "kmol/h";
     58        streamhot.Outlet.T = (70+273.15)   * "K";
     59        streamhot.Outlet.P = 5                  * "bar";
     60        streamhot.Outlet.z = [1,0];
    6161       
    6262#++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
     
    6464#++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
    6565
    66         streamcold.F = 5                        * "kmol/h";
    67         streamcold.P = 5                * "bar";
    68         streamcold.T = (25+273.15)      * "K";
    69     streamcold.z = [0,1];
     66        streamcold.Outlet.F = 5                         * "kmol/h";
     67        streamcold.Outlet.P = 5                 * "bar";
     68        streamcold.Outlet.T = (25+273.15)       * "K";
     69    streamcold.Outlet.z = [0,1];
    7070#=====================================================================
    7171#       Fouling
     
    7575       
    7676OPTIONS
    77 mode            = "steady";
     77
     78Dynamic = false;
    7879
    7980end
Note: See TracChangeset for help on using the changeset viewer.