trunk/eml/heat_exchangers/DoublePipe.mso
r110 r129 454 454 455 455 "Overall Heat Transfer Coefficient Clean" 456 Details.Uc*(Resistances.Rtube+Resistances.Rwall+Resistances.Rshell)=1;456 (1/Details.Ud)=(1/Details.Uc)+Resistances.Rfo+Resistances.Rfi*(DoInner/DiInner); 457 457 458 458 "Overall Heat Transfer Coefficient Dirty" 459 Details.Ud*(Resistances.Rfi*(DoInner/DiInner) + Resistances.Rfo + Resistances.Rtube + Resistances.Rwall + Resistances.Rshell)=1; 459 Details.Ud=1/(DoInner/(Inner.HeatTransfer.hcoeff*DiInner)+Resistances.Rfo+Resistances.Rfi*(DoInner/DiInner)+(DoInner*ln(DoInner/DiInner)/(2*Kwall))+(1/(Outer.HeatTransfer.hcoeff))); 460 460 461 461 462 end -
trunk/eml/heat_exchangers/HEX_Engine.mso
r110 r129 252 252 #===================================================================== 253 253 VARIABLES 254 A as area (Brief="Exchange Surface Area" );254 A as area (Brief="Exchange Surface Area",Lower=1e-6); 255 255 Q as power (Brief="Heat Transfer", Default=7000, Lower=1e-6, Upper=1e10); 256 256 Uc as heat_trans_coeff (Brief="Overall Heat Transfer Coefficient Clean",Default=1,Lower=1e-6,Upper=1e10);