source: mso/template/flowsheet.mso @ 78

Last change on this file since 78 was 33, checked in by Argimiro Resende Secchi, 17 years ago

clean up.

  • Property svn:eol-style set to native
  • Property svn:keywords set to Id
File size: 2.2 KB
Line 
1#*
2 * EMSO template file for new flowsheets.
3 *
4 * The user should edit the contents of this file in order
5 * to develop a new flowsheet.
6 *
7 * $Id: flowsheet.mso 33 2006-09-23 00:28:32Z arge $
8 *#
9
10#*
11 * The using command makes available entities declared in another files.
12 *
13 * With this command the user can make use of the EML models
14 *#
15using "stage_separators/flash";
16
17#*
18 * A new flowsheet is declared with the FlowSheet keyword and a name.
19 * A flowhseet can have several sections presented above:
20 *#
21FlowSheet MyFlowSheet
22        #*
23         * In the PARAMETERS section we can define the constants of the
24         * FlowSheet. When the model requires thermodynamic calculations
25         * we should create an special parameter called PP and select
26         * the model and components of the mixture, as follows:
27         *#
28        PARAMETERS
29        PP      as CalcObject(Brief="Physical Properties", File="vrpp");
30        NComp   as Integer;
31        SET
32        PP.Components = ["1,3-butadiene", "isobutene", "n-pentane", "1-pentene"];
33        PP.LiquidModel = "PR";
34        PP.VapourModel = "PR";
35        NComp = PP.NumberOfComponents;
36       
37        #*
38         * In the DEVICES section the components of the process are declared.
39         * Each device is based in a previously defined mathematical model, coming
40         * from the EML or developed by the user.
41         *#
42        DEVICES
43        STR101   as stream_therm;
44        FLASH101 as flash;
45
46        #*
47         * Once the devices of the process were declared we can connect them
48         * in the CONNECTIONS section
49         *#
50        CONNECTIONS
51        STR101     to   FLASH101.Inlet;
52
53        #*
54         * In order to simulate the process the user should specify some variables
55         *#
56        SPECIFY
57        STR101.F = 496.3 * "kmol/h";
58        STR101.T = 338 * "K";
59        STR101.P = 507.1 * "kPa";
60        STR101.v = 0.1380;
61        STR101.z = [0.2379, 0.3082, 0.09959, 0.35431];
62
63        FLASH101.OutletV.F = 68.5 * "kmol/h";
64        FLASH101.OutletL.F = 400*sqrt(FLASH101.Level) * "kmol/h";
65        FLASH101.Q = 1 * "kJ/h";
66       
67        #*
68         * We can adjust the parameters of the devices in any point after
69         * its declaration.
70         *#
71        SET
72        FLASH101.V = 2000 * "m^3";
73        FLASH101.Across = 1 * "m^2";     
74         
75        #*
76         * Besides the usual specifications, dynamic models require the specification
77         * of initial conditions.
78         *#
79        INITIAL
80        FLASH101.OutletL.T = 330 *"K";
81        FLASH101.Level = 1 * "m";